Return To Previous Page

~ Menu ~
Chemical Dispenser Kit
How does it Work?
Replacement Chemicals
Installation Help
Warranty Information

Blue Streak Chemical ~ Automatic Chemical Metering System for RV Toilets

Installation Instructions

~ Select your Potty ~

Thetford Aqua-MagicŪ Aurora

1.       Remove the stool to access the back.

A.  Remove two bolts, one in the front by the pedal and one in the rear.
B.  Remove the water line located at the rear of the stool.
     ( MAKE SURE WATER IS OFF )

 
2.       Locate flush line between vacuum breaker and bowl.

A.  Cut line half way between the two.
 
B.  Insert T-valve with small arrow pointing towards bowl.
     ( THIS IS VERY IMPORTANT )

 
C.  With the two hose clamps enclosed in kit, secure T- valve in place. 

     (Photo Views 1 & 2)

 

3.       Reinstall stool making sure all gaskets, 
          bolts and water connections are secure.


View 1


View 2

4.       Mounting the dispenser reservoir to the wall.

A.  Locate reservoir to the back or side of the wall providing easy access for filling.
B.  Keep level or lower than back of stool.
C.  Screw reservoir into place with the three screws provided with kit.

  
5.       FINAL CHECK LIST
A.  Check water line for leaks.
B.  Check stool by flushing.
C.  Add a few ounces of
Blue Streak Chemical to reservoir.
D.  Flush stool. Finish filling reservoir.

Thetford Aqua-MagicŪ Galaxy/Starlight
1.       Remove the stool to access the back.

A.  Remove two bolts, one in the front by the pedal and one in the rear ( or the plug located at the top of the stool ).
B.  Remove the water line located at the rear of the stool.
     ( MAKE SURE WATER IS OFF )

 
2.       Locate flush line between vacuum breaker and bowl.

A.  Cut line half way between the two.
 
B.  Insert T-valve with small arrow pointing towards bowl.
     ( THIS IS VERY IMPORTANT )
  
C.  With the two hose clamps enclosed in kit, secure T- valve in place. 
    
(Photo View 1)

Click here for full diagram of assembly & Parts


View 1

3.       Reinstall stool making sure all gaskets, 
          bolts and water connections are secure.
 
4.       Mounting the dispenser reservoir to the wall.

A.  Locate reservoir to the back or side of the wall providing easy access for filling.
B.  Keep level or lower than back of stool.
C.  Screw reservoir into place with the three screws provided with kit.

  
5.       FINAL CHECK LIST
A.  Check water line for leaks.
B.  Check stool by flushing.
C.  Add a few ounces of
Blue Streak Chemical to reservoir.
D.  Flush stool. Finish filling reservoir.

 

Parts & Assembly Diagram

   

Thetford Aqua-MagicŪ IV

A. Remove two bolts, one on each side.
 
B. Remove water line located at the rear of stool.
    ( MAKE SURE WATER IS OFF )

 
2.     Locate flush line between vacuum breaker and bowl.

A.  Remove two bolts, one on each side.
     1. Remove eight (8) screws from under rim.
     2. Gently pry apart.
[Photo 2A]


2A

B.  Cut a small section out of flush line.
     ( Between two smooth sections.)
  
C.  Using a hair dryer, warm plastic line so it can easily slip over T-valve. The arrow on the T-valve should point toward the bowl.
     ( THIS IS VERY IMPORTANT )
 
D.  With the two clamps provided, secure T-valve in place.  
[Photo 2B-D]


2B-D

E.  At the back of the base, drill a 11/32 hole in the flat section for line supply.
 
F.  Feed line through hole. 
     ( A tight fit is necessary to avoid any leaks.)
[Photo 2E-F]


2E-F

G.  Reassemble stool making sure blade spring is in place.
 
H.  Reattach ž line to reservoir. Apply silicone on stem.

 
3.     Reinstall stool making sure all gaskets, 
        bolts and water connections are secure.

      
4.     Mounting the dispenser on the wall.

A.  Locate reservoir to the back or side of the wall providing easy access for filling.
 
B.  Keep level or lower than back of stool.
 
C.  Screw reservoir into place with the three screws provided with the kit.

 
5.     FINAL CHECK LIST

A.  Check water lines for leaks.
 
B.  Check stool by flushing.
 
C.  Add a few ounces of Blue Streak Chemical to reservoir.
 
D.  Flush Stool. Finish filling reservoir.

Sealand 510 and 910 Traveler
1.       Locate flush line at rear of stool.

A.  Cut line just below vacuum breaker.
B.  Insert T-valve with arrow pointing towards vacuum breaker.
C.  Secure in place with two clamps provided with kit.

2.       Mounting the dispenser reservoir to the wall

A.  Locate reservoir to the back or side of the wall providing easy access for filling.
B.  Keep level or lower than back of stool.
C.  Screw reservoir into place with the three screws provided with kit.

3.       FINAL CHECK LIST

A.  Check the stool by flushing.
B.  Check the water line for leaks.
C.  Add a few ounces of
Blue Streak Chemical to reservoir.
D.  Flush stool. Finish filling reservoir.

Thetford Bravura

A. Remove front cover at base of stool.

A. Remove two bolts, one on each side.
 
B. Remove water line located at the rear of stool.
    ( MAKE SURE WATER IS OFF )

 
2.     Locate flush line between vacuum breaker and bowl.

A.  Flush Line enters back of stool going to the bowl.

B. Cut line about half way.

C. Install T-valve with arrow pointed toward the bowl.

D. With the clamps provided, secure T-valve in place.
    
[Photo View 1]

 

View 1

 3.    Reinstall stool making sure all gaskets, bolts, water connections and front cover are secure.
 

4.     Mounting the dispenser on the wall.

A. Locate reservoir to the back or side wall, providing easy access for filling.

B. Keep reservoir lower than the stool. [Photo View 2]
  
C. Screw reservoir into place with three screws provided with kit.


View 2

 
5.     FINAL CHECK LIST

A.  Check water lines for leaks.
 
B.  Check stool by flushing.
 
C.  Add a few ounces of Blue Streak Chemical to reservoir.

D. Flush stool. Finish filling reservoir.

Thetford Aqua-MagicŪ V
1.       Remove the stool.

A.  Remove two bolts, one on each side.

B.  Remove the water line located at the rear of the stool.
     ( MAKE SURE WATER IS OFF )

2.       Locate flush line between vacuum breaker and bowl.

A. Flush line is located to left rear of stool. 
    
[Photo View 1]

B.  Cut a small section out of the flush line.
 
C.  Install T-valve with small arrow pointing towards bowl.

 
D.  With the clamps provided, secure T- valve in place. 
    
[Photo View 2]

3.       Reinstall stool, making sure all gaskets, 
          bolts and water connections are secure.


View 1


View 2

 
4.       Mounting the dispenser reservoir to the wall.

A.  Locate reservoir to the back or side wall providing easy access for filling.
B.  Keep level or lower than back of stool.
C.  Screw reservoir into place with the three screws provided with kit.

  
5.       FINAL CHECK LIST
A.  Check water line for leaks.
B.  Check stool by flushing.
C.  Add a few ounces of
Blue Streak Chemical to reservoir.
D.  Flush stool. Finish filling reservoir.





How The Blue Streak Dispenser Works

The Blue Streak Dispenser is a chemical injector that adds a metered amount of chemical to the flush line of RV stools. 

The t-valve is a venturi that creates a vacuum to draw the chemical from the reservoir and mixes it with the water passing through the t-valve.  The t-valve also contains a check valve to stabilize the systems between flushes. On the side of the t-valve is a small arrow, which indicates the direction the water needs to flow through it to create a vacuum.
If installed backwards it will not draw chemical from the reservoir.

The metering tip controls how much chemical to water ratio (or mix) you get in the stool. The approximate mix is one ounce chemical to five gallons of water. It should give you a color mix that is between a royal blue and a sky blue in the stool.
The tip is preset and there is no adjustment.

The reservoir, which is mounted on the wall, should be no higher than the top of the stool. It can be mounted lower than the stool or in a basement compartment.
If the reservoir is mounted higher than the stool, the chemical will flow freely into the bowl and give you a very dark blue color.

If you remove the line from the reservoir always be sure to use silicone sealer on the fitting when reattaching the line.  The mold line on the stem sometimes will allow chemical to leak out if you don't.

The tube pinch on the line between the tank and the t-valve is a service clamp, only for use when repairing the stool, or to stop the flow of the chemical.